Field Testing
Paving Checklist
Temperature
- Ambient Air: Does it meet minimums?
- Pavement Surface: Does it meet minimums?
- Mix Delivery temperature:
- Is mix below maximum production temperature?
- Is mix above minimum paving specifications?
- Infrared vs Probe thermometer: Confirm calibration of temperature gauges and probe thermometers.
- Thermal Camera: Operate per mfg’s recommendations.
Mat Density
- Gauge (Tex‑207‑F, Part 3) QF207-3
- Establish Roller Pattern Tex-207-F Part 4 QF207-4 Core (Tex‑251‑F, Part I and Part II). QF251 As required, use agency random numbers to locate. Cool surface, proper handling, and chain of command on extracted core.
- Establish daily and running correlation between gauge and core values.
Longitudinal Joint Density
Segregation
Permeability
- As required, verify QC testing and QA testing. (Tex-246-F) QF246
- Porous Friction Course (PFC): Max 20 seconds
- Thin Overlay Mix (TOM): Min 120 seconds
Sampling Binders and Tack
Sign up for checklist updates and new resources from Texas Asphalt Pavement Association.