- Ensure vertical faces are tacked (except PFC longitudinal joints).
- Maintain proper overlap with screed when matching joint to eliminate hand working joint.
- Do not push mix away from joint.
- Bumping mix to edge of joint is acceptable if needed.
- Longitudinal joint: Keep the majority of roller drum on hot mat overlapping to pinch joint, or hold off 6 inches on first pass and overlap on return pass.